 ====== Peak Lock and Current Controller Command Set ====== ====== Peak Lock and Current Controller Command Set ======
  
-List of commands for the ICE Quad Temperate Controller. Please see [[ice:commands:lasercurrent|Common Laser Controller Command Set]] for commands relating to the laser controller.+List of commands for the ICE Peak Lock Servo. Please see [[ice:commands:lasercurrent|Common Laser Controller Command Set]] for commands relating to the laser controller.
  
 <function=ICEfunc|0=Phase?&2=58&3=32> <function=ICEfunc|0=Phase?&2=58&3=32>
Line 69: Line 69:
  
 <function=ICEfunc|0=OpOffst&1=I:OFFSET:142;&2=142&3=46> <function=ICEfunc|0=OpOffst&1=I:OFFSET:142;&2=142&3=46>
-Sets the Integrator Op-Amp’s Offset Voltage adjustment value. This should be factory set, but it controls the DC Error Input voltage that the servo locks to (should be 0V) OFFSET is an integer from 0-255. Returns the output of the command **OpOffst?**.+Sets the Integrator Op-Amp’s Offset Voltage adjustment value. This should be factory set and typically should be set to 128, but it controls the DC Error Input voltage that the servo locks to (should be 0V) OFFSET is an integer from 0-255. Returns the output of the command **OpOffst?**.
 <html></div></html> <html></div></html>
  
Line 111: Line 111:
  
 <function=ICEfunc|0=RampNum&1=I:NUMBER:100&2=100&3=54> <function=ICEfunc|0=RampNum&1=I:NUMBER:100&2=100&3=54>
-Sets the number of data points to be acquired during the ramp. Number of data points is also the number of steps for the ramp. Number of data points to calculated by the following formula:+Sets the number of data points to be acquired during the ramp. Number of data points is also the number of steps for the ramp. 
  
 <html></div></html> <html></div></html>
Line 120: Line 120:
  
 <function=ICEfunc|0=Poles?&2=3 0&3=56> <function=ICEfunc|0=Poles?&2=3 0&3=56>
-Returns two columns of data. First column is a number 1-5 representing the integrator pole value. (slowest integratorfastest). The second column is a 0 when the differential pole is off and a 1 when it is on.+Returns two columns of data. First column is a number 1-5 representing the integrator pole value. Values are 3 kHz, 10 kHz, 30 kHz, 100 kHz and 300 kHz. is the slowest integrator (3 kHz) and is fastest integrator (300 kHz). The second column is a 0 when the differential pole is off and a 1 when it is on. When differential is on, the pole is ~3 times the integrator pole. So if PI pole is 30 kHz, the differential pole is 100 kHz