d2:power_supply
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
d2:power_supply [2022/08/23 20:14] – external edit 127.0.0.1 | d2:power_supply [2023/02/01 21:10] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 26: | Line 26: | ||
=====Description===== | =====Description===== | ||
- | The Power Supply is a quiet, linear power supply providing +/-15V and 5V. It is in a separate box to isolate 60 Hz and EM interference. One power supply can power two complete laser systems, or four electronics modules. | + | The Power Supply is a quiet, linear power supply providing +/-15V and 5V. It is in a separate box to isolate |
+ | |||
+ | =====Symbols===== | ||
+ | A list of symbols which appear on the D2-005, and their definitions, | ||
+ | |||
+ | {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | {{: | ||
Line 40: | Line 52: | ||
Nothing must obstruct airflow from the top panel vent. Never place anything on top of the D2-005. | Nothing must obstruct airflow from the top panel vent. Never place anything on top of the D2-005. | ||
</ | </ | ||
+ | <WRAP center round important 60%> | ||
+ | A potential hazard exists if the D2-005 comes into contact with water or other conductive liquids, and exposure to these should be avoided. | ||
+ | </ | ||
+ | |||
+ | Special care must be given to replacing the provided mains power cord, such that any replacement cords are appropriately rated. | ||
+ | If the D2-005 is used in a manner not specified by Vescent or in this manual, the protection provided by the equipment may be impaired. | ||
=====Purchase Includes===== | =====Purchase Includes===== | ||
* D2-005 Power Supply | * D2-005 Power Supply | ||
Line 49: | Line 67: | ||
===== Absolute Maximum Ratings ===== | ===== Absolute Maximum Ratings ===== | ||
- | Note: All modules designed to be operated in laboratory environment with filtered air. There are no known altitude restrictions on the D2-005. | + | Note: All modules designed to be operated in an indoor |
<WRAP center round box 60%> | <WRAP center round box 60%> | ||
| **Parameter** | **Rating** | | | **Parameter** | **Rating** | | ||
Line 73: | Line 91: | ||
</ | </ | ||
+ | Replaceable fuses located in the power entry module are rated at 2A, 250V @115VAC or 1A, 250V @230VAC | ||
+ | =====Intended Use===== | ||
+ | The D2-005 is intended to supply low-noise DC electrical power to the following Vescent D2 products: | ||
+ | *D2-105 Laser Controller | ||
+ | *D2-125 Reconfigurable Laser Servo | ||
+ | *D2-135 Offset Phase Lock Servo | ||
+ | *D2-210 Spectroscopy Module | ||
+ | *D2-260 Beat Note Detector | ||
=====Inputs, | =====Inputs, | ||
Line 84: | Line 109: | ||
The monitor section contains three blue status LEDs indicating proper voltage on the +15,-15, and 5V power lines. If there is a voltage sag on any of the power lines, the blue status LED will turn off. | The monitor section contains three blue status LEDs indicating proper voltage on the +15,-15, and 5V power lines. If there is a voltage sag on any of the power lines, the blue status LED will turn off. | ||
+ | ====Front Panel Controls==== | ||
+ | A single switch on the front panel of the D2-005 toggles whether power is enabled or disabled. Flipping the switch to the " | ||
+ | |||
+ | <WRAP center round important 60%> | ||
+ | Do not position the D2-005 such that it is difficult to operate the switch. | ||
+ | </ | ||
====Back panel I/O==== | ====Back panel I/O==== | ||
Line 92: | Line 123: | ||
</ | </ | ||
- | <WRAP center round important 60%> | ||
- | If you are considering using an Uninterruptible Power Supply (UPS) to guarantee operation of your Vescent products through a brown out or black out, great care should be taken in choosing the model. | ||
- | </ | ||
- | Power is supplied to the D2-005 via a standard C13 to Type-B power cord. The power to each electronics | + | Power is supplied to the D2-005 via a standard C13 to Type-B power cord. Connections |
{{ : | {{ : | ||
- | While it is infrequent, the D2-005 | + | In some system configurations, the D2-005 |
+ | |||
+ | <WRAP center round important 60%> | ||
+ | If you are considering using an Uninterruptible Power Supply (UPS) to guarantee operation of your Vescent products through a brown out or black out, great care should be taken in choosing the model. | ||
+ | </ |
d2/power_supply.1661285677.txt.gz · Last modified: 2022/08/23 20:14 by 127.0.0.1