 The Power Supply is a quiet, linear power supply providing +/-15V and 5V. It is in a separate box to isolate 60 Hz and EM interference. One power supply can power two complete laser systems, or four electronics modules. The Power Supply is a quiet, linear power supply providing +/-15V and 5V. It is in a separate box to isolate 60 Hz and EM interference. One power supply can power two complete laser systems, or four electronics modules.
 +
 +=====Purchase Includes=====
 +  * D2-005 Power Supply
 +  * VPN00464 Power Cord
 +
 +
 +
  
 ===== Absolute Maximum Ratings ===== ===== Absolute Maximum Ratings =====
Line 55: Line 62:
  
 **Power I/O (9-pin D-sub)** **Power I/O (9-pin D-sub)**
 +<WRAP center round important 60%>
 +Always turn off the D2-005, make connections to the device, and then re-energize the D2-005.  Never connect this D2-005 Power Supply to a device when it is switched on and supplying power. 
 +</WRAP>
 +
 +<WRAP center round important 60%>
 +If you are considering using an Uninterruptible Power Supply (UPS) to guarantee operation of your Vescent products through a brown out or black out, great care should be taken in choosing the model.  Lower cost models tend to produce modified square wave voltage profiles.  The high-frequency components of such a voltage profile may interact poorly with the D2-005 (and down-stream active Vescent modules).  If you do choose to use a UPS, select a model that will provide a sine wave voltage profile without higher harmonic components to avoid potential damage to your high-value equipment.
 +</WRAP>
  
 The power to each electronics module is through a 9-pin D-sub connector through a power bridge unit.  The unit can also be powered through any serial cable with 9-pin D-sub connectors, which is convenient when the unit must be taken out of line for access to the side panels.  The pin outs are shown in the following figure: The power to each electronics module is through a 9-pin D-sub connector through a power bridge unit.  The unit can also be powered through any serial cable with 9-pin D-sub connectors, which is convenient when the unit must be taken out of line for access to the side panels.  The pin outs are shown in the following figure:
d2/power_supply.txt · Last modified: 2023/02/01 21:10 by 127.0.0.1