Line 110: Line 110:
 ---- ----
 <function=ICEfunc|0=Beta&1=I:CHANNEL:2;F:VALUE:3450&2=3450.0&-1> <function=ICEfunc|0=Beta&1=I:CHANNEL:2;F:VALUE:3450&2=3450.0&-1>
-For the B-parameter thermistor model: Sets the Beta coefficient in Kelvin [K] to VALUE for CHANNEL. Returns **Beta?**. Execute a TEMPLUT command after setting Beta through the API (QC firmware versions 1.14 & lower).+For the B-parameter thermistor model: Sets the Beta coefficient in Kelvin [K] to VALUE for CHANNEL. Returns **Beta?**.  When a new Beta-parameter is set, new Steinhart-Hart coefficients are calculated. Execute a TEMPLUT command after setting Beta through the API (QC firmware versions 1.14 & lower).
 ---- ----
 <function=ICEfunc|0=RefTemp?&1=I:CHANNEL:1&2=25.0&-1> <function=ICEfunc|0=RefTemp?&1=I:CHANNEL:1&2=25.0&-1>
Line 116: Line 116:
 ---- ----
 <function=ICEfunc|0=RefTemp&1=I:CHANNEL:2;F:VALUE:25.0&2=25.0&-1> <function=ICEfunc|0=RefTemp&1=I:CHANNEL:2;F:VALUE:25.0&2=25.0&-1>
-For the B-parameter thermistor model: Sets the Reference Temperature in degrees Celsius [˚C] to VALUE for CHANNEL. Returns **RefTemp?**. Execute a TEMPLUT command after setting the Reference Temperature through the API (QC firmware versions 1.14 & lower).+For the B-parameter thermistor model: Sets the Reference Temperature in degrees Celsius [˚C] to VALUE for CHANNEL. Returns **RefTemp?**. When a new Reference Temperature is set, new Steinhart-Hart coefficients are calculated. Execute a TEMPLUT command after setting the Reference Temperature through the API (QC firmware versions 1.14 & lower).
 ---- ----
 <function=ICEfunc|0=RefRes?&1=I:CHANNEL:1&2=10000.0&-1> <function=ICEfunc|0=RefRes?&1=I:CHANNEL:1&2=10000.0&-1>
Line 143: Line 143:
 ---- ----
 <function=ICEfunc|0=TEMPLUT&1=I:CHANNEL:1&2=&-1> <function=ICEfunc|0=TEMPLUT&1=I:CHANNEL:1&2=&-1>
-Forces recalculation of T = ƒ(A,B,C) lookup table.  There is no output from this command.  Execute this command after setting any of the Steinhart-Hart coefficients, Beta Parameter, or Reference Temperature via the API (QC firmware versions 1.14 & lower).+Forces recalculation of T = ƒ(A,B,C) lookup table.  There is no output from this command.  Execute this command after setting any of the Steinhart-Hart coefficients, Beta-parameter, or Reference Temperature via the API (QC firmware versions 1.14 & lower).
 ---- ----