User Tools

Site Tools


slice:qt:api

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
slice:qt:api [2019/10/29 21:50] – [Loop Filter Settings] Michael Radunskyslice:qt:api [2019/10/30 00:19] – [Thermistor Settings] Michael Radunsky
Line 128: Line 128:
 ---- ----
 <function=ICEfunc|0=TCoefA&1=I:CHANNEL:1;F:VALUE:2.108508173&2=2.108508173&-1> <function=ICEfunc|0=TCoefA&1=I:CHANNEL:1;F:VALUE:2.108508173&2=2.108508173&-1>
-For the Steinhart-Hart thermistor model: Sets the A coefficient to VALUE for CHANNEL. Returns **TCoefA?**.+For the Steinhart-Hart thermistor model: Sets the A coefficient to VALUE for CHANNEL. Returns **TCoefA?**. Execute a TEMPLUT command after setting any of the Steinhart-Hart coefficients through the API (QC firmware versions 1.14 & lower).
 ---- ----
 <function=ICEfunc|0=TCoefB?&1=I:CHANNEL:1&2=0.797204727&-1> <function=ICEfunc|0=TCoefB?&1=I:CHANNEL:1&2=0.797204727&-1>
Line 134: Line 134:
 ---- ----
 <function=ICEfunc|0=TCoefB&1=I:CHANNEL:1;F:VALUE:0.797204727&2=0.797204727&-1> <function=ICEfunc|0=TCoefB&1=I:CHANNEL:1;F:VALUE:0.797204727&2=0.797204727&-1>
-For the Steinhart-Hart thermistor model: Sets the B coefficient to VALUE for CHANNEL. Returns **TCoefB?**.+For the Steinhart-Hart thermistor model: Sets the B coefficient to VALUE for CHANNEL. Returns **TCoefB?**. Execute a TEMPLUT command after setting any of the Steinhart-Hart coefficients through the API (QC firmware versions 1.14 & lower).
 ---- ----
 <function=ICEfunc|0=TCoefC?&1=I:CHANNEL:1&2=6.535076315&-1> <function=ICEfunc|0=TCoefC?&1=I:CHANNEL:1&2=6.535076315&-1>
Line 140: Line 140:
 ---- ----
 <function=ICEfunc|0=TCoefC&1=I:CHANNEL:1;F:VALUE:6.535076315&2=6.535076315&-1> <function=ICEfunc|0=TCoefC&1=I:CHANNEL:1;F:VALUE:6.535076315&2=6.535076315&-1>
-For the Steinhart-Hart thermistor model: Sets the C coefficient to VALUE for CHANNEL. Returns **TCoefC?**.+For the Steinhart-Hart thermistor model: Sets the C coefficient to VALUE for CHANNEL. Returns **TCoefC?**. Execute a TEMPLUT command after setting any of the Steinhart-Hart coefficients through the API (QC firmware versions 1.14 & lower). 
 +---- 
 +<function=ICEfunc|0=TEMPLUT&1=I:CHANNEL:1&2=&-1> 
 +Forces recalculation of T = ƒ(A,B,C) lookup table.  There is no output from this command.  Execute this command after setting any of the Steinhart-Hart coefficients via the API (QC firmware versions 1.14 & lower).
 ---- ----
 ===== Loop Filter Settings ===== ===== Loop Filter Settings =====
slice/qt/api.txt · Last modified: 2023/12/06 20:33 by Christiana Sasser