User Tools

Site Tools


slice:qt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
slice:qt [2020/09/01 18:52] – [SLICE-QTC Four-Channel Temperature Controller] Michael Radunskyslice:qt [2020/09/22 14:10] – [Specifications] Michael Radunsky
Line 8: Line 8:
  
 Please read [[:limited_warranty|Limited Warranty]] and [[:warnings_cautions|General Warnings and Cautions]] prior to operating the SLICE-QTC. Please read [[:limited_warranty|Limited Warranty]] and [[:warnings_cautions|General Warnings and Cautions]] prior to operating the SLICE-QTC.
-Temporary edit 
- 
  
 ==== Links ==== ==== Links ====
Line 74: Line 72:
 | Channels                                                                                                                                  | 4                                                                                                                                                                                                                      | | Channels                                                                                                                                  | 4                                                                                                                                                                                                                      |
 | Loop Filter                                                                                                                               | PID, adjustable corners and proportional Gain                                                                                                                                                                          | | Loop Filter                                                                                                                               | PID, adjustable corners and proportional Gain                                                                                                                                                                          |
-| Control Range((Lower precision may be realized above 50°C.  Consider using a thermistor with 10 kΩ at higher temperature than nominal.))  | -10 to +120°C                                                                                                                                                                                                          |+| Control Range  | -10 to +120°C                                                                                                                                                                                                          |
 | Compatible Transducer                                                                                                                     | TEC or resistive heater                                                                                                                                                                                                | | Compatible Transducer                                                                                                                     | TEC or resistive heater                                                                                                                                                                                                |
 | Compatible Sensor                                                                                                                         | NTC thermistor ((Nominal value 10 kΩ at room temperature. Precision at temperatures removed from room temperature can be improved by selecting a thermistor whose resistance is ~10 kΩ near the target temperature.))  | | Compatible Sensor                                                                                                                         | NTC thermistor ((Nominal value 10 kΩ at room temperature. Precision at temperatures removed from room temperature can be improved by selecting a thermistor whose resistance is ~10 kΩ near the target temperature.))  |
slice/qt.txt · Last modified: 2023/08/11 15:53 by 127.0.0.1