slice:qt [2019/05/17 19:57] – [Table] Michael Radunskyslice:qt [2019/12/04 20:04] – [Proper Usage] Michael Radunsky
Line 27: Line 27:
   * AC power cord with appropriate wall plug for you location (if known)   * AC power cord with appropriate wall plug for you location (if known)
   * Four single-ended 6-ft control cables((More cables may be purchased separately; order p/n 50-00005))   * Four single-ended 6-ft control cables((More cables may be purchased separately; order p/n 50-00005))
 +  * Final Test Documentation
  
 ===== Absolute Maximum Ratings and Power Input ===== ===== Absolute Maximum Ratings and Power Input =====
Line 50: Line 51:
 ===== Proper Usage ===== ===== Proper Usage =====
 | {{ :warning-sign.png?100&nolink }}  | If this instrument is used in a manner not specified by the manufacturer in this manual or other relevant literature, protection provided by the instrument may be impaired. | | {{ :warning-sign.png?100&nolink }}  | If this instrument is used in a manner not specified by the manufacturer in this manual or other relevant literature, protection provided by the instrument may be impaired. |
 +|:::| Successful implementation of the SLICE-QTC depends critically on the design of the whole system: controller, transducer, plant, and sensor. |
 +
 +==== Tips for Successful Temperature Regulation ==== 
 +  -  The transducer, plant, and sensor must all be in good thermal contact. Use thermal paste or epoxy to avoid air gaps between a TEC or heater and the body of the plant as well as to secure the thermistor to the plant.
 +  - Know the electrical limits of of your transducer and set the limits of the SLICE-QTC accordingly.  Each channel can provide up to  6 A or 20 W of power with a maximum compliance voltage up to ~18 V.  Choose transducers that work within these limits.  Using the current, power, and/or voltage ratings of your transducer to calculate loads on individual channels and set limits appropriately in the CH X > Settings > Load Limits window.
 +  - Maintain proper shielding of the control cable, but avoid ground loops between the SLICE-QTC and the plant.  In most cases this means extending the foil shield in the cable to as close as possible to the plant without electrically connecting the SLICE-QTC to the plant.  
  
 ===== List of Symbols ===== ===== List of Symbols =====
Line 64: Line 71:
 | **Parameter**                                                                                                                             | **Value**                                                                                                                                                                                                              | | **Parameter**                                                                                                                             | **Value**                                                                                                                                                                                                              |
 | Channels                                                                                                                                  | 4                                                                                                                                                                                                                      | | Channels                                                                                                                                  | 4                                                                                                                                                                                                                      |
-| Loop FIlter                                                                                                                               | PID, adjustable corners and proportional Gain                                                                                                                                                                          |+| Loop Filter                                                                                                                               | PID, adjustable corners and proportional Gain                                                                                                                                                                          |
 | Control Range((Lower precision may be realized above 50°C.  Consider using a thermistor with 10 kΩ at higher temperature than nominal.))  | -10 to +120°C                                                                                                                                                                                                          | | Control Range((Lower precision may be realized above 50°C.  Consider using a thermistor with 10 kΩ at higher temperature than nominal.))  | -10 to +120°C                                                                                                                                                                                                          |
 | Compatible Transducer                                                                                                                     | TEC or resistive heater                                                                                                                                                                                                | | Compatible Transducer                                                                                                                     | TEC or resistive heater                                                                                                                                                                                                |
 | Compatible Sensor                                                                                                                         | NTC thermistor ((Nominal value 10 kΩ at room temperature. Precision at temperatures removed from room temperature can be improved by selecting a thermistor whose resistance is ~10 kΩ near the target temperature.))  | | Compatible Sensor                                                                                                                         | NTC thermistor ((Nominal value 10 kΩ at room temperature. Precision at temperatures removed from room temperature can be improved by selecting a thermistor whose resistance is ~10 kΩ near the target temperature.))  |
 | Temperature Stability                                                                                                                     | ±0.2 mK over 1 hour((Plant-dependent; value specified for D2-100 laser))                                                                                                                                               | | Temperature Stability                                                                                                                     | ±0.2 mK over 1 hour((Plant-dependent; value specified for D2-100 laser))                                                                                                                                               |
-| Precision                                                                                                                                 | ~1 mK                                                                                                                                                                                                                   +| Precision                                                                                                                                 | ~1 mK                                                                                                                                                                                                                  
-| Control Capacity                                                                                                                          | 35 W((User-distributable over four channels))                                                                                                                                                                          | +| Control Capacity                                                                                                                          | 40 total((User-distributable over four channels)) \\ 20 W max for a single channel                                                                                                                                                                          | 
-| Current Capacity                                                                                                                          | 6 A per channel((Subject to 35 W overall maximum))                                                                                                                                                                     |+| Current Capacity                                                                                                                          | 6 A per channel((Subject to 40 W overall maximum))                                                                                                                                                                     |
 | Compliance Voltage                                                                                                                        | ≤18 V((automatically adjusted))                                                                                                                                                                                        | | Compliance Voltage                                                                                                                        | ≤18 V((automatically adjusted))                                                                                                                                                                                        |
 |  **Input & Output**                                                                                                                                                                                                                                                                                                                                               || |  **Input & Output**                                                                                                                                                                                                                                                                                                                                               ||
Line 80: Line 87:
 | Connections                                                                                                                               | Host control: USB Type B                                                                                                                                                                                               | | Connections                                                                                                                               | Host control: USB Type B                                                                                                                                                                                               |
 </tabcaption></WRAP> </tabcaption></WRAP>
 +
 +==== Extendable Legs ====
 +The SLICE-QTC has four extendable legs (<imgref belly>).  Extending the front legs allows easy viewing from above (<imgref qt_prod_shot>) and extending the rear legs (<imgref side>) allows easy viewing from below.
 +
 +<WRAP half column><imgcaption belly|Underside of SLICE-QTC>{{ :slice:dcc:dcc_underbelly_labelled.png |}}</imgcaption>
 +</WRAP>
 +<WRAP half column><imgcaption side|Side view of SLICE-QTC configured for viewing from below>{{ : slice:dcc:slice-dcc_looking_down.png?400 |}}</imgcaption></WRAP>
  
 ===== Front Panel ===== ===== Front Panel =====
Line 119: Line 133:
 </WRAP> </WRAP>
  
-You may purchase more cables separately from Vescent Photonics.  We do not recommend making cables, but if you do so, make sure the metal sleeve is well grounded to provide proper shielding to the signal cables.+You may purchase more cables separately from Vescent Photonics.  We do not recommend making cables, but if you do so, make sure the metal sleeve is well connected to the connector ground to provide proper shielding to the signal cables.
  
 ===== Operating the SLICE-QTC ===== ===== Operating the SLICE-QTC =====
Line 153: Line 167:
 In most instances, there are two methods for entering parameter values: the physical rotary knobs on the front panel and the pop-up keypad on the touch screen.  When using the knobs to change the value of a parameter, changes take effect immediately.  When using the keypad, changes do not take effect until the enter key is depressed. In most instances, there are two methods for entering parameter values: the physical rotary knobs on the front panel and the pop-up keypad on the touch screen.  When using the knobs to change the value of a parameter, changes take effect immediately.  When using the keypad, changes do not take effect until the enter key is depressed.
 === Rotary Knobs === === Rotary Knobs ===
-If you touch an editable field for a brief moment, a cursor will appear under one of the digits of the parameter value.  By turning the right knob, it is possible to increase (cw) or decrease (ccw) the value of the underlined digit.  Turning the left knob will change which digit is editable (cw to move to the left and ccw to move to the right).  +If you touch an editable field for a brief moment, a cursor will appear under one of the digits of the parameter value.  By turning the right knob, it is possible to increase (cw) or decrease (ccw) the value of the underlined digit.  Turning the left knob will change which digit is editable (cw to move to the right and ccw to move to the left).  
 == Keypad == == Keypad ==
 If you touch and hold an editable field such as the set point temperature, a numeric keypad will appear as seen in <imgref keypad> You can enter in the full value of the desired parameter with this keypad.\\  If you touch and hold an editable field such as the set point temperature, a numeric keypad will appear as seen in <imgref keypad> You can enter in the full value of the desired parameter with this keypad.\\ 
Line 176: Line 190:
 To set the temperature set point from the home screen, touch the Setpoint window for the desired channel (circled in red for CH 1 in <imgref home_Tset1>).  A long touch will cause a keypad to appear.  Enter desired value and touch the accept button.  To set the temperature set point from the home screen, touch the Setpoint window for the desired channel (circled in red for CH 1 in <imgref home_Tset1>).  A long touch will cause a keypad to appear.  Enter desired value and touch the accept button. 
  
-A short touch will highlight the Setpoint window in yellow (<imgref home_Tset2>).  Use rotary knobs to select digit to edit (right knob) and value for digit (left knob).\\+A short touch will highlight the Setpoint window in yellow (<imgref home_Tset2>).  Use rotary knobs to select digit to edit (left knob) and value for digit (right knob).\\
 <imgcaption home_Tset1|Select Temperature setpoint for CH 1>{{ :slice:slice-qt_set_t_home_1.png?400x254 |}}</imgcaption> <imgcaption home_Tset1|Select Temperature setpoint for CH 1>{{ :slice:slice-qt_set_t_home_1.png?400x254 |}}</imgcaption>
  
Line 342: Line 356:
 Change the input impedance of the two front-panel input ports.  Select either 50 Ω or 1 MΩ. Change the input impedance of the two front-panel input ports.  Select either 50 Ω or 1 MΩ.
  
-=== Firmware Version ===+=== SLICE-QT Firmware ===
 Current firmware versions are reported here.   Current firmware versions are reported here.  
  
-<WRAP center round box 60%><tabcaption firmware_rev |Most recent firmware versions>+<WRAP center round box 60%><tabcaption firmware_rev |Most recent firmware versions as of 6 June 2019>
 | Firmware | Version Level | Release Date | | Firmware | Version Level | Release Date |
 | System Controller| 1.24| 23 May 2019| | System Controller| 1.24| 23 May 2019|
Line 368: Line 382:
 It is possible to control the SLICE-QTC from a Windows<sup>®</sup>-based PC using a GUI.  In order to use the GUI, you must first download the latest version, connect the PC to the SLICE-QTC, and assign a COM port to the SLICE-QTC.  The following describes the steps involved. It is possible to control the SLICE-QTC from a Windows<sup>®</sup>-based PC using a GUI.  In order to use the GUI, you must first download the latest version, connect the PC to the SLICE-QTC, and assign a COM port to the SLICE-QTC.  The following describes the steps involved.
  
-  - Download and store the latest GUI executable from the FTP site (Request copy of executable GUI from [[[email protected]|sales [at] vescent [dot] com]]).+  - Download and store the latest GUI executable from [[ https://github.com/Vescent| the Vescent FTP site]] (or request copy of executable GUI from [[[email protected]|sales [at] vescent [dot] com]]).
   - Connect the SLICE-QTC to the PC using a USB type B cable.   - Connect the SLICE-QTC to the PC using a USB type B cable.
   - Turn on the SLICE-QTC.   - Turn on the SLICE-QTC.
slice/qt.txt · Last modified: 2023/08/11 15:53 by 127.0.0.1