slice:qt [2019/04/02 15:11] – [Channel Settings] Michael Radunskyslice:qt [2019/04/02 16:17] – [SLICE-QT Four-Channel Temperature Controller] Michael Radunsky
Line 9: Line 9:
 Please read [[:limited_warranty|Limited Warranty]] and [[:warnings_cautions|General Warnings and Cautions]] prior to operating the SLICE-QT. Please read [[:limited_warranty|Limited Warranty]] and [[:warnings_cautions|General Warnings and Cautions]] prior to operating the SLICE-QT.
  
 +==== Links ====
 Click here for the [[slice:quick_start_qt|SLICE-QT Quick Start Guide]].\\ Click here for the [[slice:quick_start_qt|SLICE-QT Quick Start Guide]].\\
 Click here for the [[slice:qt:API|SLICE-QT API]].\\ Click here for the [[slice:qt:API|SLICE-QT API]].\\
 +Click here for the [[slice:Z-N|Ziegler-Nichols loop tuning instructions]].\\
 Click here for the [[https://www.vescent.com/products/electronics/slice/slice-qt-four-channel-temperature-controller/|SLICE-QT web page]].\\ Click here for the [[https://www.vescent.com/products/electronics/slice/slice-qt-four-channel-temperature-controller/|SLICE-QT web page]].\\
 Please check back for added functionality.  Contact [[[email protected]|sales [at] vescent [dot] com]] for questions and corrections, or to request added functionality. Please check back for added functionality.  Contact [[[email protected]|sales [at] vescent [dot] com]] for questions and corrections, or to request added functionality.
Line 209: Line 211:
 <imgcaption PID|Screen for adjusting PID parameters for individual channel>{{ :slice:slice-qt_ch_1_pid_param_screen_set_p_gain.jpg?400x254 |}}</imgcaption> <imgcaption PID|Screen for adjusting PID parameters for individual channel>{{ :slice:slice-qt_ch_1_pid_param_screen_set_p_gain.jpg?400x254 |}}</imgcaption>
  
-To set the PID loop filter parameters from the Home screen, select CH X > Settings > PID Params and the screen in <imgref PID> will appear.  The parameters for the PID loop filter are set in this popup screen. These parameters control the closed-loop behavior of the feedback. Each of these parameters will need to be tuned specifically for your plant. There is an option to enable or disable each parameter in the loop filter.  There are a number of methods to tune a loop.  We recommend the [[Z-N|Ziegler-Nichols method]].((A usable discussion of the Ziegler-Nichols method can be found here: http://faculty.mercer.edu/jenkins_he/documents/TuningforPIDControllers.pdf)) +To set the PID loop filter parameters from the Home screen, select CH X > Settings > PID Params and the screen in <imgref PID> will appear.  The parameters for the PID loop filter are set in this popup screen. These parameters control the closed-loop behavior of the feedback. Each of these parameters will need to be tuned specifically for your plant. There is an option to enable or disable each parameter in the loop filter.  There are a number of methods to tune a loop.  We recommend the Ziegler-Nichols method.(([[https://staff.guilan.ac.ir/staff/users/chaibakhsh/fckeditor_repo/file/documents/Optimum%20Settings%20for%20Automatic%20Controllers%20(Ziegler%20and%20Nichols,%201942).pdf|Optimum Settings for Automatic Controllers, by J.G. Zieger and N. B. Nichols]] and\\ 
 +[[https://en.wikipedia.org/wiki/Ziegler%E2%80%93Nichols_method|Wikipedia]]))  [[Z-N|Instructions on using this method can be found here]].
  
 == Slew Rate Limit == == Slew Rate Limit ==