slice:dhv:api [2020/05/26 23:49] Michael Radunskyslice:dhv:api [2020/05/27 00:47] – [Set Source of Modulation Signal for CH 2: MODEB] Michael Radunsky
Line 363: Line 363:
  
   * In the example, CHANNEL 1 will henceforth respond to Trigger In.   * In the example, CHANNEL 1 will henceforth respond to Trigger In.
-  * To query Error Code, use [[slice:dhv:api#Query_Response_to_Trigger_In:_TRIGIN?|TRIGIN?]] command.+  * To query response to trigger input, use [[slice:dhv:api#Query_Response_to_Trigger_In:_TRIGIN?|TRIGIN?]] command.
  
 ---- ----
  
 +==== Query Trigger Out Meaning: TRIGOUT? ====
  
-==== Query Response to Trigger In: TRIGIN====+<function=ICEfunc|0=TRIGOUT?&1=I:CHANNEL:1&2=1&-1> 
 +Returns the meaning of the Trigger Out signal with respect to CHANNEL as seen in <tabref trigout?>.
  
-<function=ICEfunc|0=TRIGIN?&1=I:CHANNEL:1&2=1&-1> +<WRAP center round box 60%><tabcaption trigout?|Possible return values & meaning for TTL high at the Trigger Out> 
-Returns the effect of Trigger In signal on CHANNEL as seen in <tabref trigin?>.+^  Response  ^  Meaning 
 +| 0 |  No change in state of the Trigger Out based state of CHANNEL 
 +| 1 |  The signal at Trigger Out will go high in sync with the ramp on CHANNEL 
 +</tabcaption></WRAP> 
 + 
 +  * In the example, the signal at Trigger Out will go high in sync with the ramp on CH 1. 
 +  * To set the meaning of the Trigger Out signal, use [[slice:dhv:api#Set_Trigger_Out:_TRIGOUT|TRIGOUT]] 
 + 
 +---- 
 + 
 +==== Set Trigger Out: TRIGOUT ==== 
 + 
 +<function=ICEfunc|0=TRIGOUT&1=I:CHANNEL:1;I:Selection:1&2=1&-1> 
 +Returns TRIGOUT? for CHANNEL. 
 + 
 +<WRAP center round box 60%><tabcaption trigout|> 
 +^  Selection  ^  Meaning of Trigger Out with respect to CHANNEL 
 +| 0 |  Trigger out is unresponsive to state of CHANNEL 
 +| 1 |  A TTL high signal at Trigger Out will be in sync with ramp of CHANNEL  | 
 +</tabcaption></WRAP> 
 + 
 +  * In the example, Trigger Out will go high in sync with ramp on CH 1  
 +  * To query Trigger Out meaning, use [[slice:dhv:api#Query_Trigger_Out_Meaning:_TRIGOUT?|TRIGOUT?]] command 
 +  * Setting the Trigger Out to be in sync with CH 1 removes Trigger Out's synchronicity with CH 2 & vice versa 
 + 
 +---- 
 + 
 +==== Query Source of Modulation Signal for CH 1: MODEA? ==== 
 + 
 +<function=ICEfunc|0=MODEA?&1&2=257&-1> 
 +Returns from where CH 1 receives modulation control as seen in <tabref modea?>.
  
-<WRAP center round box 60%><tabcaption trigin?|Possible return values & meaning for TRIGIN? command>+<WRAP center round box 60%><tabcaption modea?|Possible return values & meaning MODEA? command>
 ^  Response  ^  Meaning  ^ ^  Response  ^  Meaning  ^
-| 0 |  Trigger In status has no effect on CHANNEL  | +| 0 |  CH 1 accepts its modulation signal from rear-panel SMA connector  | 
-|  High signal on Trigger In enables CHANNEL. Low signal on Trigger In disables CHANNEL  |+257 |  CH 1 accepts its modulation signal from front-panel Input A BNC connector  |
 </tabcaption></WRAP> </tabcaption></WRAP>
  
-  * In the example, CH 1 will respond to a Trigger In signal. +  * In the example, CH 1 accepts its modulation signal from the front-panel Input A
-  * To set the response to Trigger In signal, use [[slice:dhv:api#Set_Response_to_Trigger_In:_TRIGIN|TRIGIN]]+  * To set from where CH 1 accepts modulation signal, use [[slice:dhv:api#Set_Source_of_Modulation_Signal_for_CH_1:_MODEA|MODEA]] 
 +  * Only one modulation source may be active at a time
  
 ---- ----
  
-==== Set Response to Trigger InTRIGIN ====+==== Set Source of Modulation Signal for CH 1MODEA ====
  
-<function=ICEfunc|0=TRIGIN&1=I:CHANNEL:1;I:Selection:1&2=1&-1> +<function=ICEfunc|0=MODEA&1=I:MODE:1:1&2=257&-1> 
-Returns TRIGINfor CHANNEL.+Returns MODEA?
  
-<WRAP center round box 60%><tabcaption trigin|> +<WRAP center round box 60%><tabcaption modea|> 
-^  Selection  ^  Programmed Response to Trigger In  ^ +^  Mode  ^  Location of modulation input for CH 1  ^ 
-| 0 |  CHANNEL will not respond to Trigger In  | +| 0 |  CH 1 accepts modulation signal from rear-panel SMA connector  | 
-| 1 |  High signal on Trigger In enables CHANNEL. Low signal on Trigger In disables CHANNEL  |+| 1 |  CH 1 accepts modulation signal from front-panel Input A BNC connector  |
 </tabcaption></WRAP> </tabcaption></WRAP>
  
-  * In the example, CHANNEL 1 will henceforth respond to Trigger In. +  * In the example, CH 1 will accept a modulation signal from the front-panel Input A BNC 
-  * To query Error Code, use [[slice:dhv:api#Query_Response_to_Trigger_In:_TRIGIN?|TRIGIN?]] command.+  * To query the modulation source for CH 1, use [[slice:dhv:api#Query_Source_of_Modulation_Signal_for_CH_1:_MODEA?|MODEA?]] command
  
 ---- ----
  
 +
 +==== Query Source of Modulation Signal for CH 2: MODEB? ====
 +
 +<function=ICEfunc|0=MODEB?&1&2=257&-1>
 +Returns from where CH 2 receives modulation control as seen in <tabref modeb?>.
 +
 +<WRAP center round box 60%><tabcaption modeb?|Possible return values & meaning MODEB? command>
 +^  Response  ^  Meaning  ^
 +| 0 |  CH 2 accepts its modulation signal from rear-panel SMA connector  |
 +| 257 |  CH 2 accepts its modulation signal from front-panel Input B BNC connector  |
 +</tabcaption></WRAP>
 +
 +  * In the example, CH 2 accepts its modulation signal from the front-panel Input B.
 +  * To set from where CH B accepts a modulation signal, use [[slice:dhv:api#Set_Source_of_Modulation_Signal_for_CH_2:_MODEB|MODEB]]
 +  * Only one modulation source may be active at a time
 +
 +----
 +
 +==== Set Source of Modulation Signal for CH 2: MODEB ====
 +
 +<function=ICEfunc|0=MODEB&1=I:MODE:1:1&2=257&-1>
 +Returns MODEB?
 +
 +<WRAP center round box 60%><tabcaption modea|>
 +^  Mode  ^  Location of modulation input for CH 2  ^
 +| 0 |  CH 2 accepts modulation signal from rear-panel SMA connector  |
 +| 1 |  CH 2 accepts modulation signal from front-panel Input B BNC connector  |
 +</tabcaption></WRAP>
 +
 +  * In the example, CH 2 will henceforth accept a modulation signal from the front-panel Input B BNC
 +  * To query the modulation source for CH 2, use [[slice:dhv:api#Query_Source_of_Modulation_Signal_for_CH_2:_MODEB?|MODEB?]] command
 +
 +----
  
slice/dhv/api.txt · Last modified: 2023/12/06 20:39 by Christiana Sasser