User Tools

Site Tools


ice:pcb_mechanics

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
ice:pcb_mechanics [2014/07/02 18:19] – [PCB Stackup] jtshugrueice:pcb_mechanics [2014/07/02 18:24] – Added another sil pad figure ref jtshugrue
Line 2: Line 2:
 This page presents the mechanical specifications for PCB's in the ICE Platform when being integrated by an OEM. This page presents the mechanical specifications for PCB's in the ICE Platform when being integrated by an OEM.
 ===== PCB Dimensions ===== ===== PCB Dimensions =====
-All PCB's in the ICE Platform follow identical board dimensions and header/mounting hole locations. The PCB's themselves are 4 inches square and contain 4 mounting holes for 4-40 screws on each corner. The dimensions of the boards are shown in <imgref singlePCB>. All contain a power bus header on each side ([[http://cloud.samtec.com/catalog_english/ESQ_TH.PDF|Samtec PN: ESQ-106-13-T-D]]) and a digital communications bus header ([[http://cloud.samtec.com/catalog_english/ESQ_TH.PDF|Samtec PN: ESQ-104-13-T-D]]) in the middle of the PCB. These headers are 0.1 inch pitch board-to-board headers that allow interconnection between boards when stacked, as shown in the [[pcb_mechanics#PCB Stackup|next section]]. At the edge of the board there are copper tabs extending from four IC's (TO-220 package) for heatsinking. Details on proper heatsinking are described in a [[pcb_mechanics#Thermal Management|later section]]. Note that not all boards will utilize all four heatsinking positions.+All PCB's in the ICE Platform follow identical board dimensions and header/mounting hole locations. The PCB's themselves are 4 inches square and contain 4 mounting holes for 4-40 screws on each corner. The dimensions of the boards are shown in <imgref singlePCB>. All contain a power bus header on each side ([[http://cloud.samtec.com/catalog_english/ESQ_TH.PDF|Samtec PN: ESQ-106-13-T-D]]) and a digital communications bus header ([[http://cloud.samtec.com/catalog_english/ESQ_TH.PDF|Samtec PN: ESQ-104-13-T-D]]) in the middle of the PCB. These headers are 0.1 inch pitch board-to-board headers that allow interconnection between boards when stacked, as shown in the [[pcb_mechanics#PCB Stackup|next section]]. At the edge of the board there are copper tabs extending from four IC's (TO-220 package) for heatsinking. Details on proper heatsinking are described in a [[pcb_mechanics#Thermal Management|later section]].  
 + 
 +<WRAP center round info 60%> 
 +Not all circuit boards will utilize all four heatsinking positions and therefore may have copper tabs in only a few positions. The four possible tab positions shown in the drawings will are fixed for every board even though a copper tab may not be utilized there. 
 +</WRAP>
  
 <imgcaption singlePCB|PCB dimensions.>{{ :ice:single_pcb_dimensions.png?800 |}}</imgcaption> <imgcaption singlePCB|PCB dimensions.>{{ :ice:single_pcb_dimensions.png?800 |}}</imgcaption>
Line 18: Line 22:
 </WRAP> </WRAP>
 ===== Thermal Management ===== ===== Thermal Management =====
-Each PCB exposes up to 4 copper tabs to conduct heat out from power dissipating components to an external heat sink. The copper tabs are not electrically isolated, so electrical isolation is **required** at the interface between the heatsink and copper tab. Failure to isolate these tabs will result in malfunction of the ICE module. For electrical isolation with good thermal conductivity, [[http://www.bergquistcompany.com/thermal_materials/sil-pad.htm|Sil-Pad]] can be used. Sil-Pad requires a certain amount of pressure to ensure good thermal conductivity, so a clamp mechanism should be applied to the copper tabs. In the <imgref stackup3>, the Sil-Pad is shown in pink. In the [[ice:enclosure|ICE Platform]] enclosure, a wedge-based clamping system is used. The mechanics and dimensions of this are detailed below+Each PCB exposes up to 4 copper tabs to conduct heat out from power dissipating components to an external heat sink. The copper tabs are not electrically isolated, so electrical isolation is **required** at the interface between the heatsink and copper tab. Failure to isolate these tabs will result in malfunction of the ICE module. For electrical isolation with good thermal conductivity, [[http://www.bergquistcompany.com/thermal_materials/sil-pad.htm|Sil-Pad]] can be used. Sil-Pad requires a certain amount of pressure to ensure good thermal conductivity, so a clamp mechanism should be applied to the copper tabs. In the <imgref singlePCB> and <imgref stackup3>, the Sil-Pad is shown in pink. In the [[ice:enclosure|ICE Platform]] enclosure, a wedge-based clamping system is used. The mechanics and dimensions of this are detailed below
 <WRAP center round important 60%> <WRAP center round important 60%>
 The copper tabs **must** be electrically isolated from the heatsink. For electrical isolation with good thermal conductivity, [[http://www.bergquistcompany.com/thermal_materials/sil-pad.htm|Sil-Pad]] can be used. The copper tabs **must** be electrically isolated from the heatsink. For electrical isolation with good thermal conductivity, [[http://www.bergquistcompany.com/thermal_materials/sil-pad.htm|Sil-Pad]] can be used.
ice/pcb_mechanics.txt · Last modified: 2021/08/26 15:26 by 127.0.0.1