 <function=ICEfunc|0=TempSet?&1=I:CHANNEL:3&2=26.283&3=16> <function=ICEfunc|0=TempSet?&1=I:CHANNEL:3&2=26.283&3=16>
-Returns the temperature setpoint for channel Channel. +Returns the temperature setpoint for channel CHANNEL.
-<html></div></html>+
  
 <function=ICEfunc|0=TempSet&1=I:CHANNEL:3;F:TEMP:24.55&2=24.548&3=17> <function=ICEfunc|0=TempSet&1=I:CHANNEL:3;F:TEMP:24.55&2=24.548&3=17>
Line 13: Line 12:
 //Note: temperature setpoint cannot be set outside of the bounds of the minimum and maximum temperature.  //Note: temperature setpoint cannot be set outside of the bounds of the minimum and maximum temperature. 
 If TEMP is outside that range, temperature setpoint will not be adjusted.// If TEMP is outside that range, temperature setpoint will not be adjusted.//
-<html></div></html> 
  
 <function=ICEfunc|0=BiPolar?&1=I:CHANNEL:3&2=On&3=18> <function=ICEfunc|0=BiPolar?&1=I:CHANNEL:3&2=On&3=18>
-Returns whether the temperature loop for channel CHANNEL is bipolar.  +Returns whether the temperature loop for channel CHANNEL is bipolar.
-<html></div></html>+
  
 <function=ICEfunc|0=BiPolar&1=I:CHANNEL:3;A:On/Off:Off&2=Off&3=19> <function=ICEfunc|0=BiPolar&1=I:CHANNEL:3;A:On/Off:Off&2=Off&3=19>
 Sets the temperature loop for channel CHANNEL bipolar (heating only) on or off.  Sets the temperature loop for channel CHANNEL bipolar (heating only) on or off. 
 Turn Bipolar off when driving resistive heaters. Returns output from **BiPolar?**. Turn Bipolar off when driving resistive heaters. Returns output from **BiPolar?**.
-<html></div></html> 
  
 <function=ICEfunc|0=Servo?&1=I:CHANNEL:3&2=Off&3=20> <function=ICEfunc|0=Servo?&1=I:CHANNEL:3&2=Off&3=20>
Line 28: Line 24:
 A return of fault means that the temperature is outside the min/max temperature range and that the  A return of fault means that the temperature is outside the min/max temperature range and that the 
 temperature loop has been temporarily disabled. temperature loop has been temporarily disabled.
-<html></div></html> 
  
 <function=ICEfunc|0=Servo&1=I:CHANNEL:3;A:On/Off:On&2=On&3=21> <function=ICEfunc|0=Servo&1=I:CHANNEL:3;A:On/Off:On&2=On&3=21>
-Turns the temperature servo loop for channel CHANNEL on or off.  Returns the output of **Servo?**  +Turns the temperature servo loop for channel CHANNEL on or off.  Returns the output of **Servo?**
-<html></div></html>+
  
 <function=ICEfunc|0=Temp?&1=I:CHANNEL:3&2=24.21&3=22> <function=ICEfunc|0=Temp?&1=I:CHANNEL:3&2=24.21&3=22>
 Returns the current temperature for channel CHANNEL.   Returns the current temperature for channel CHANNEL.  
-<html></div></html> 
  
 <function=ICEfunc|0=TError?&1=I:CHANNEL:3&2=0.021&3=23> <function=ICEfunc|0=TError?&1=I:CHANNEL:3&2=0.021&3=23>
-Returns the temperature error (T<sub>setpoint</sub> – T<sub>actual</sub>) in degrees Celcius.+Returns the temperature error (T<sub>setpoint</sub> – T<sub>actual</sub>) in degrees Celsius.
 <html></div></html> <html></div></html>
  