fcc:100:api [2021/10/18 23:02] – external edit 127.0.0.1fcc:100:api [2021/10/18 23:17] – external edit 127.0.0.1
Line 42: Line 42:
 For most complete version of API, download the FFC-Serial API PDF from the [[fcc:100:api#Links|downloads]] section. For most complete version of API, download the FFC-Serial API PDF from the [[fcc:100:api#Links|downloads]] section.
  
-=====New Table=====+=====General Commands=====
 <function=ICEfunc|0=#Version&1=&2=255.255 255.255 0.16 65535 (0.16 is version)&-1> <function=ICEfunc|0=#Version&1=&2=255.255 255.255 0.16 65535 (0.16 is version)&-1>
 Returns firmware version of master board where arguments are used as follows: Returns firmware version of master board where arguments are used as follows:
Line 65: Line 65:
 Sets the touch screen and rotary knob audio feedback volume Sets the touch screen and rotary knob audio feedback volume
 ---- ----
-<function=ICEfunc|0=*IDN?&1=&2=Vescent Photonics,FFC,[serial#],S-[version],FL-[version],LD-[version],LD-[version]&-1>+<function=ICEfunc|0= *IDN?&1=&2=Vescent Photonics,FFC,[serial#],S-[version],FL-[version],LD-[version],LD-[version]&-1>
 Returns the Manufacturer, Model, Serial Number, Board Firmware Versions  of the device Returns the Manufacturer, Model, Serial Number, Board Firmware Versions  of the device
 ---- ----
-<function=ICEfunc|0=*RST&1=&2=Resetting System&-1>+<function=ICEfunc|0= *RST&1=&2=Resetting System&-1>
 Restarts the device (power cycle) Restarts the device (power cycle)
 ---- ----
Line 79: Line 79:
  
  
-=====New Table=====+=====Control API=====
 <function=ICEfunc|0=MSTRCTL?&1=&2=MSTRCTL? 0&-1> <function=ICEfunc|0=MSTRCTL?&1=&2=MSTRCTL? 0&-1>
 Returns the enumerated operating mode of the FFC Returns the enumerated operating mode of the FFC
Line 163: Line 163:
  
  
-=====FFC Temperature Controls=====+=====Temperature Controls=====
 <function=ICEfunc|0=CATSETP?&1=&2=CATSETP? 20.3&-1> <function=ICEfunc|0=CATSETP?&1=&2=CATSETP? 20.3&-1>
 Returns the temperature setpoint for the Cavity Temperature Control Returns the temperature setpoint for the Cavity Temperature Control
Line 657: Line 657:
  
  
-=====New Table=====+=====Laser Current Controls=====
 <function=ICEfunc|0=OSISETP?&1=&2=OSISETP? 997.939941&-1> <function=ICEfunc|0=OSISETP?&1=&2=OSISETP? 997.939941&-1>
 Reads the Current Setpoint for the Oscillator Laser [mA]  Reads the Current Setpoint for the Oscillator Laser [mA] 
Line 772: Line 772:
  
  
-=====New Table=====+=====Laser PZT Controls=====
 <function=ICEfunc|0=CADCBSP?&1=&2=CADCBSP? 60.000000&-1> <function=ICEfunc|0=CADCBSP?&1=&2=CADCBSP? 60.000000&-1>
 Reads the DC Bias Setpoint for the Cavity [V] Reads the DC Bias Setpoint for the Cavity [V]