Line 27: Line 27:
   * D2-210 Spectroscopy Module   * D2-210 Spectroscopy Module
   * VPN00463 SMA cable (6ft)   * VPN00463 SMA cable (6ft)
-Also look for: 
   * VPN00410 Hirose-to-D Sub 9-pin (shipped under separate line item; specify for use with D2)   * VPN00410 Hirose-to-D Sub 9-pin (shipped under separate line item; specify for use with D2)
   * VPN00475 Hirose-to-Hirose power cord (shipped under separate line item; specify for use with ICE)   * VPN00475 Hirose-to-Hirose power cord (shipped under separate line item; specify for use with ICE)
 +  * VPN00367 Adjustment tool
  
  
Line 125: Line 125:
 **Temperature Bias Adj.** **Temperature Bias Adj.**
  
-For the Doppler subtraction option this control enables the user to input a small temperature difference between the reference and signal vapor cells.  In the fully CCW position the signal vapor cell heater gets all the current.  In the full CW position the reference cell heater gets twice the current as the signal cell.  This adjustment can be used to place the optimum point for Doppler Subtraction closer to zero Volts.+[Note: this adjustment is only available on older D2-210 models.] For the Doppler subtraction option this control enables the user to input a small temperature difference between the reference and signal vapor cells.  In the fully CCW position the signal vapor cell heater gets all the current.  In the full CW position the reference cell heater gets twice the current as the signal cell.  This adjustment can be used to place the optimum point for Doppler Subtraction closer to zero Volts.
  
 This adjustment only has an effect with the -DS, Doppler Subtraction option. This adjustment only has an effect with the -DS, Doppler Subtraction option.
Line 190: Line 190:
  
  
-The following images are representative of spectroscopy for <sup>87</sup>Rb with and without Doppler subtraction.  Note that Doppler subtraction has a minimal effect on peak lock signal generated by dithering the laser (green traces).+The following images are representative of spectroscopy for <sup>87</sup>Rb with and without Doppler subtraction.  Note that Doppler subtraction (<imgref ds>has a minimal effect on peak lock signal generated by dithering the laser (green traces).
  
 +<imgcaption image1|Pin numbering on female Hirose 6-pin connector>{{  :d2:d2-160:hirose-connector.png?200  }}</imgcaption>
  
-{{ :d2:d2-210:sas.jpg?nolink |}} +<imgcaption no-ds|Non-Doppler subtracted side- and peak-lock spectra>{{ :d2:d2-210:sas.jpg?nolink |}}</imgcaption> 
-{{ :d2:d2-210:sas_w_ds.jpg?nolink |}}+<imgcaption ds|Doppler subtracted side- and peak-lock spectra>{{ :d2:d2-210:sas_w_ds.jpg?nolink |}}</imgcaption>